metal/mtce
Eric MacDonald 4e132af308 Mtce: fix hbsClient active monitoring over config reload
The maintenance process monitor is failing the hbsClient
process over config or process reload operations.

The issue relates to the hbsClient's subfunction being
'last-config' without pmon properly gating the active
monitoring FSM from starting until the passive monitoring
phase is complete and in the MANAGE state.

Test Plan

PASS: Verify active monitoring failure detection and handling
PASS: Verify proper process monitoring over pmond config reload
PASS: Verify proper process monitoring over SIGHUP -> pmond
PASS: Verify proper process monitoring over SIGUSR2 -> pmond
PASS: Verify proper process monitoring over process failure recovery
PASS: Verify pmond regression test soak ; on active and inactive controllers
PASS: Verify pmond regression test soak ; on compute node
PASS: Verify pmond regression test soak ; kill/recovery function
PASS: Verify pmond regression test soak ; restart function
PASS: Verify pmond regression test soak ; alarming function
PASS: Verify pmond handles critical process failure with no restart config
PASS: Verify pmond handles ntpd process failure

PASS: Verify AIO DX Install
PASS: Verify AIO DX Inactive Controller process management over Lock/Unlock.

Change-Id: Ie2fe7b6ce479f660725e5600498cc98f36f78337
Closes-Bug: 1807724
Signed-off-by: Eric MacDonald <eric.macdonald@windriver.com>
2018-12-12 13:53:18 -05:00
..
centos Mtce: fix hbsClient active monitoring over config reload 2018-12-12 13:53:18 -05:00
src Mtce: fix hbsClient active monitoring over config reload 2018-12-12 13:53:18 -05:00
PKG-INFO Decouple Guest-server/agent from stx-metal 2018-09-18 17:15:08 -04:00