cc53f1e689
When the Hardware Monitor starts up it reads existing alarms and sensor state from the sysinv database. It then uses this pre-existing state to align its internal structure accordingly moving forward. The hardware monitor manage_startup_states utility is incorrectly requesting degrade clear rather than degrade set in response to finding a pre-existing critical sensor assertion on process startup. This update fixes this issue by calling the set_degraded_state rather than clear_degraded_state against this sensor in this case. Change-Id: Ic1ecc1f11d7a729c16da63c6d43b7d758bb9e467 Signed-off-by: David Sullivan <david.sullivan@windriver.com> Story: 2002882 Task: 22845 |
||
---|---|---|
.. | ||