1350502720
If a host's BMC server accepts a power-off command without error but does not actually power-off the host, the power-off FSM reports success yet the host power is still on. This update adds a verification component to the power-off FSM. Once the power-off command is issued and succeeds at the command level, the power-off FSM will now query power status and retry the power-off command until the server is verified to be powered-off or the retry max (10) is reached and the power-off command is failed. Test Plan: PASS: Verify 200+ Mtce Power Off/On cycles (ipmi & redfish) PASS: Verify 100+ Mtce Reinstalls with FIT (ipmi & redfish) Change-Id: Iddd120d89d1152fc0b26915df123f586c38b909b Closes-Bug: 1865087 Signed-off-by: Eric MacDonald <eric.macdonald@windriver.com> |
||
---|---|---|
.. | ||
centos | ||
opensuse | ||
src | ||
PKG-INFO |