Merge "Manual Tests: Maintenance"
This commit is contained in:
commit
6ad0f6f945
|
@ -18,3 +18,4 @@ For more information about StarlingX, see https://docs.starlingx.io/.
|
||||||
networking/index
|
networking/index
|
||||||
storage/index
|
storage/index
|
||||||
security/index
|
security/index
|
||||||
|
maintenance/index
|
||||||
|
|
|
@ -0,0 +1,328 @@
|
||||||
|
===========
|
||||||
|
Maintenance
|
||||||
|
===========
|
||||||
|
|
||||||
|
This test plan covers maintenance manual regression. It covers basic
|
||||||
|
functionality for the following features.
|
||||||
|
|
||||||
|
- PTP (Precision Time Protocol)
|
||||||
|
- Port fail management and/or OAM
|
||||||
|
- Collectd + InfluxDb - RMON Replacement (ALL METRICS)
|
||||||
|
|
||||||
|
--------------------
|
||||||
|
Overall Requirements
|
||||||
|
--------------------
|
||||||
|
|
||||||
|
Any TIS system can be used.
|
||||||
|
|
||||||
|
----------
|
||||||
|
Test Cases
|
||||||
|
----------
|
||||||
|
|
||||||
|
.. contents::
|
||||||
|
:local:
|
||||||
|
:depth: 1
|
||||||
|
|
||||||
|
~~~~~~~~~
|
||||||
|
MTC_PTP_1
|
||||||
|
~~~~~~~~~
|
||||||
|
|
||||||
|
:Test ID: MTC_PTP_1
|
||||||
|
:Test Title: test_configure_PTP_Service_using_GUI
|
||||||
|
:Tags: P1 MTC, PTP, regression
|
||||||
|
|
||||||
|
++++++++++++++++++
|
||||||
|
Testcase Objective
|
||||||
|
++++++++++++++++++
|
||||||
|
|
||||||
|
Purpose of this test is to validate configuration of PTP from GUI
|
||||||
|
and verify alarm cleared.
|
||||||
|
|
||||||
|
+++++++++++++++++++
|
||||||
|
Test Pre-Conditions
|
||||||
|
+++++++++++++++++++
|
||||||
|
|
||||||
|
++++++++++
|
||||||
|
Test Steps
|
||||||
|
++++++++++
|
||||||
|
|
||||||
|
1. Launch horizon and login as admin
|
||||||
|
2. Open System Configuration page in horizon
|
||||||
|
3. Click PTP and edit.
|
||||||
|
4. Check mark to enabled
|
||||||
|
5. Save verify out of configuration 250.001
|
||||||
|
6. Lock and unlock all the nodes starting with standby controller.
|
||||||
|
7. After all the nodes are bring locked and unlock and they are up.
|
||||||
|
8. Verify Configuration out-of-date alarms are cleared for both
|
||||||
|
controllers.
|
||||||
|
|
||||||
|
+++++++++++++++++
|
||||||
|
Expected Behavior
|
||||||
|
+++++++++++++++++
|
||||||
|
|
||||||
|
Able to edit the PTP from horizon GUI.
|
||||||
|
|
||||||
|
~~~~~~~~~
|
||||||
|
MTC_PTP_2
|
||||||
|
~~~~~~~~~
|
||||||
|
|
||||||
|
:Test ID: MTC_PTP_2
|
||||||
|
:Test Title: test_PTP_service_clock_sync_with_time_change_and_reboot_host
|
||||||
|
:Tags: P1 MTC, PTP, regression
|
||||||
|
|
||||||
|
++++++++++++++++++
|
||||||
|
Testcase Objective
|
||||||
|
++++++++++++++++++
|
||||||
|
|
||||||
|
To verify PTP service clock sync with reboot.
|
||||||
|
|
||||||
|
+++++++++++++++++++
|
||||||
|
Test Pre-Conditions
|
||||||
|
+++++++++++++++++++
|
||||||
|
|
||||||
|
Ensure all the hosts ether-net hardware is supported for software or
|
||||||
|
hardware mode transmit and receive time stamp.
|
||||||
|
E.g: Below show software mode supported ether-net:
|
||||||
|
|
||||||
|
.. code:: sh
|
||||||
|
|
||||||
|
ethtool -T <Interface>
|
||||||
|
Time stamping parameters for enp134s0f0:
|
||||||
|
Capabilities:
|
||||||
|
software-transmit (SOF_TIMESTAMPING_TX_SOFTWARE)
|
||||||
|
software-receive (SOF_TIMESTAMPING_RX_SOFTWARE)
|
||||||
|
software-system-clock (SOF_TIMESTAMPING_SOFTWARE)
|
||||||
|
PTP Hardware Clock: none
|
||||||
|
Hardware Transmit Timestamp Modes: none
|
||||||
|
Hardware Receive Filter Modes: none
|
||||||
|
|
||||||
|
++++++++++
|
||||||
|
Test Steps
|
||||||
|
++++++++++
|
||||||
|
|
||||||
|
1. Enabled PTP using following command:
|
||||||
|
|
||||||
|
.. code:: sh
|
||||||
|
|
||||||
|
system ptp-modify --enabled=True --mode=software
|
||||||
|
|
||||||
|
2. Lock and unlock all the hosts starting with standby controller to
|
||||||
|
clear alarm Configuration out-of-date alarm id 250.001
|
||||||
|
|
||||||
|
3. Verify the time all sync after lock and unlock
|
||||||
|
|
||||||
|
4. Change time Eg: date +%T -s "11:14:00" in one of the host
|
||||||
|
|
||||||
|
5. Reboot the hosts where time is change and verify time is sync with
|
||||||
|
other hosts after reboot.
|
||||||
|
|
||||||
|
++++++++++++++++++
|
||||||
|
Expected Behaviour
|
||||||
|
++++++++++++++++++
|
||||||
|
|
||||||
|
Time was sync after reboot.
|
||||||
|
|
||||||
|
|
||||||
|
~~~~~~~~~
|
||||||
|
MTC_PTP_3
|
||||||
|
~~~~~~~~~
|
||||||
|
|
||||||
|
:Test ID: MTC_PTP_3
|
||||||
|
:Test Title: test_ptp4l_process_failure_detection_by_alarm_200.006_and_recovery
|
||||||
|
:Tags: P1 MTC, PTP, regression
|
||||||
|
|
||||||
|
++++++++++++++++++
|
||||||
|
Testcase Objective
|
||||||
|
++++++++++++++++++
|
||||||
|
|
||||||
|
This test is to verify phc2sys process failure detection by alarm and
|
||||||
|
alarm clear on recovery.
|
||||||
|
|
||||||
|
+++++++++++++++++++
|
||||||
|
Test Pre-Conditions
|
||||||
|
+++++++++++++++++++
|
||||||
|
|
||||||
|
Enable PTP as per instruction- - in Test case 1 or 2
|
||||||
|
|
||||||
|
++++++++++
|
||||||
|
Test Steps
|
||||||
|
++++++++++
|
||||||
|
|
||||||
|
1. Find the process id for phc2sys
|
||||||
|
2. Use the above process id and kill the process sudo kill -9 process ID
|
||||||
|
3. Verify alarm and process restart
|
||||||
|
4. Try steps 1 and 2 to verify multiple times
|
||||||
|
|
||||||
|
+++++++++++++++++
|
||||||
|
Expected Behavior
|
||||||
|
+++++++++++++++++
|
||||||
|
|
||||||
|
Process restart on process kill and alarm
|
||||||
|
|
||||||
|
~~~~~~~~~
|
||||||
|
MTC_PTP_4
|
||||||
|
~~~~~~~~~
|
||||||
|
|
||||||
|
:Test ID: MTC_PTP_4
|
||||||
|
:Test Title: test_ptp4l_process_failure_detection_alarm_200.006_and_recovery
|
||||||
|
:Tags: P1 MTC, PTP, Regression
|
||||||
|
|
||||||
|
++++++++++++++++++
|
||||||
|
Testcase Objective
|
||||||
|
++++++++++++++++++
|
||||||
|
|
||||||
|
This test is to verify ptp4l process failure detection by alarm and alarm clear
|
||||||
|
on recovery.
|
||||||
|
|
||||||
|
+++++++++++++++++++
|
||||||
|
Test Pre-Conditions
|
||||||
|
+++++++++++++++++++
|
||||||
|
|
||||||
|
Enable PTP as per instruction in Test case 1 or 2
|
||||||
|
|
||||||
|
|
||||||
|
++++++++++
|
||||||
|
Test Steps
|
||||||
|
++++++++++
|
||||||
|
|
||||||
|
1. Find the process id for ptp4l.
|
||||||
|
2. Use the above process id and kill the process sudo kill -9 process ID
|
||||||
|
3. Verify alarm and process restart.
|
||||||
|
4. Try steps 1 and 2 to verify multiple times.
|
||||||
|
|
||||||
|
+++++++++++++++++
|
||||||
|
Expected Behavior
|
||||||
|
+++++++++++++++++
|
||||||
|
|
||||||
|
Process restart on process kill and alarm.
|
||||||
|
|
||||||
|
~~~~~~~~~~~~~~~~
|
||||||
|
MTC_MgtOAMdown_5
|
||||||
|
~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
:Test ID: MTC_MgtOAMdown_5
|
||||||
|
:Test Title: test_pull_management_cable_on_active_controller
|
||||||
|
:Tags: P1 MTC, regression
|
||||||
|
|
||||||
|
++++++++++++++++++
|
||||||
|
Testcase Objective
|
||||||
|
++++++++++++++++++
|
||||||
|
|
||||||
|
This test is to verify management cable pull on active controller
|
||||||
|
and verify standby controller becoming active with host-list available
|
||||||
|
on all the hosts except the other controller.
|
||||||
|
|
||||||
|
+++++++++++++++++++
|
||||||
|
Test Pre-Conditions
|
||||||
|
+++++++++++++++++++
|
||||||
|
|
||||||
|
Install 2+2 system.
|
||||||
|
|
||||||
|
++++++++++
|
||||||
|
Test Steps
|
||||||
|
++++++++++
|
||||||
|
|
||||||
|
1. Remove management cable from active controller(controller-0)
|
||||||
|
2. Verify alarm for communication failure
|
||||||
|
3. Verify swact to controller-1
|
||||||
|
|
||||||
|
++++++++++++++++++
|
||||||
|
Expected Behaviour
|
||||||
|
++++++++++++++++++
|
||||||
|
|
||||||
|
Controller swact and alarm for communication failure.
|
||||||
|
|
||||||
|
~~~~~~~~~~~~~~~~
|
||||||
|
MTC_MgtOAMdown_6
|
||||||
|
~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
:Test ID: MTC_MgtOAMdown_6
|
||||||
|
:Test Title: test_that_compute_host_will_reboot_if_management_network_is_down
|
||||||
|
:Tags: P1 MTC, regression
|
||||||
|
|
||||||
|
++++++++++++++++++
|
||||||
|
Testcase Objective
|
||||||
|
++++++++++++++++++
|
||||||
|
|
||||||
|
This test is to verify that management cable pull on compute node
|
||||||
|
alarm generated for communication failure.
|
||||||
|
|
||||||
|
+++++++++++++++++++
|
||||||
|
Test Pre-Conditions
|
||||||
|
+++++++++++++++++++
|
||||||
|
|
||||||
|
Install 2+2 system.
|
||||||
|
|
||||||
|
++++++++++
|
||||||
|
Test Steps
|
||||||
|
++++++++++
|
||||||
|
|
||||||
|
1. Remove management cable from compute node.
|
||||||
|
2. Verify alarm for communication failure.
|
||||||
|
3. Verify compute reboot once cable is put back.
|
||||||
|
|
||||||
|
+++++++++++++++++
|
||||||
|
Expected Behavior
|
||||||
|
+++++++++++++++++
|
||||||
|
|
||||||
|
Alarm for communication failure and reboot
|
||||||
|
|
||||||
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
MTC_collectdIusflexDbRmon_7
|
||||||
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
:Test ID: MTC_collectdIusflexDbRmon_7
|
||||||
|
:Test Title: test_ntp_connectivity_failure_alarm_and_sample_data
|
||||||
|
:Tags: P1 MTC, regression
|
||||||
|
|
||||||
|
++++++++++++++++++
|
||||||
|
Testcase Objective
|
||||||
|
++++++++++++++++++
|
||||||
|
|
||||||
|
To verify NTP connection failure alarm and sample data.
|
||||||
|
|
||||||
|
+++++++++++++++++++
|
||||||
|
Test Pre-Conditions
|
||||||
|
+++++++++++++++++++
|
||||||
|
|
||||||
|
Install 2+2 system.
|
||||||
|
|
||||||
|
++++++++++
|
||||||
|
Test Steps
|
||||||
|
++++++++++
|
||||||
|
|
||||||
|
1. Verify no alarms on NTP.
|
||||||
|
2. Verify sample data for NTP value should be 3 or 2 for
|
||||||
|
NTP connection is good and no alarms.
|
||||||
|
3. Execute below cli retrieve database info
|
||||||
|
|
||||||
|
.. code:: sh
|
||||||
|
|
||||||
|
while true; do influx -database=collectd -execute="SELECT * FROM ntpq_value
|
||||||
|
ORDER by time DESC LIMIT 4"; sleep 31; done
|
||||||
|
|
||||||
|
4. When there is no failure above sample data will showed NTP connection
|
||||||
|
failure is 1
|
||||||
|
5. Trigger a failure by update NTP server address in system configuration in
|
||||||
|
horizon to unknown.
|
||||||
|
6. Verify fm alarm list for NTP alarm for text server configuration doesn't
|
||||||
|
have reachable NTP server.
|
||||||
|
7. Query on database using below command. NTP connection
|
||||||
|
failure will be indicated by 0
|
||||||
|
|
||||||
|
.. code:: sh
|
||||||
|
|
||||||
|
while true; do influx -database=collectd -execute="SELECT * FROM
|
||||||
|
ntpq_value ORDER by time DESC LIMIT 4"; sleep 31; done
|
||||||
|
|
||||||
|
+++++++++++++++++
|
||||||
|
Expected Behavior
|
||||||
|
+++++++++++++++++
|
||||||
|
|
||||||
|
Alarm for communication failure and reboot.
|
||||||
|
|
||||||
|
----------
|
||||||
|
References
|
||||||
|
----------
|
||||||
|
|
||||||
|
https://wiki.openstack.org/wiki/StarlingX/Containers/Installation
|