High availability
|
|
=================
|
|
|
|
Titanium Clouds Service Management (SM) and Maintenance (Mtce)
|
|
Systems handle transient and persistent networking failures between
|
|
controllers and service hosts (storage/compute) For instance, a
|
|
transient loss of Management Network Carrier on the active controller
|
|
currently triggers an immediate fail-over to the standby controller even
|
|
though the very same failure may exist for that controller as well ; i.e.
|
|
it may be no more healthy that the current active controller. A persistent
|
|
loss of heartbeat messaging to several or all nodes in the system results in
|
|
the forced failure and reboot of all affected nodes once connectivity has been
|
|
re-established.In most of these cases the network event that triggered fault
|
|
handling is external to the system ; i.e. the reboot of a common messaging
|
|
switch for instance, and truly beyond the control of Titanium Cloud HA
|
|
(High Availability) Services. In such cases it's best to be more fault
|
|
tolerant/forgiving than over active.
|
|
|
|
|
|
----------------------
|
|
Overall Requirements
|
|
----------------------
|
|
|
|
This test will require access to the following configurations:
|
|
- Regular system
|
|
- Storage system
|
|
- AIO-DX systems
|
|
|
|
----------
|
|
Test Cases
|
|
----------
|
|
|
|
.. contents::
|
|
:local:
|
|
:depth: 1
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
HA_Cloud_Recovery_improvements_01
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
:Test ID: HA_Cloud_Recovery_improvements_01
|
|
:Test Title: test_split_brain_avd_activer_or_standby_based_on_only_storage_and
|
|
standby_controller_blocked_on_active_controller
|
|
:Tags: P2,HA,Recovery improvement,regression
|
|
|
|
|
|
+++++++++++++++++++
|
|
Testcase Objective
|
|
+++++++++++++++++++
|
|
Purpose of this test is to verify split brain scenario swact on active
|
|
controller by blocking standby controller and storage on active controller
|
|
|
|
++++++++++++++++++++
|
|
Test Pre-Conditions
|
|
++++++++++++++++++++
|
|
System should be a storage system
|
|
|
|
+++++++++++
|
|
Test Steps
|
|
+++++++++++
|
|
1. Using below cli disconnects management storage-0 and controller-1 active
|
|
controller-0. Execute below command to block both storage and controller
|
|
first storage should be blocked and immediately controller should be
|
|
blocked.
|
|
code::
|
|
Execute sudo iptables -I INPUT 1 -s 192.168.222.204 -j DROP
|
|
...
|
|
2. Verify connection failure alarm
|
|
3. Verify controller-1 becomes active. Verify system host-list from
|
|
controller-1
|
|
4. Reboot new standby controller-0. Once reboot complete verify system
|
|
host-list from active controller.
|
|
|
|
++++++++++++++++++
|
|
Expected Behavior
|
|
++++++++++++++++++
|
|
controller-1 becomes active
|
|
System host-list shows right states
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
HA_Cloud_Recovery_improvements_02
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
:Test ID: HA_Cloud_Recovery_improvements_02
|
|
:Test Title: test_aio_dx_direct_active_controller_lost_connection_to_standby_ip
|
|
:Tags: P2,HA,Recovery improvement,regression
|
|
|
|
+++++++++++++++++++
|
|
Testcase Objective
|
|
+++++++++++++++++++
|
|
Purpose of this test is to verify standby controller reboot when it is lost
|
|
connectivity to active controller.
|
|
|
|
++++++++++++++++++++
|
|
Test Pre-Conditions
|
|
++++++++++++++++++++
|
|
System should be AIO-DX direct connection. System should be connected to
|
|
BMC module and provisioned. If the BMC not provisioned expected behavior
|
|
there wont be reboot on standby controller
|
|
|
|
+++++++++++
|
|
Test Steps
|
|
+++++++++++
|
|
1. Block the standby ip(Management ip) from active controller.
|
|
code::
|
|
iptables -I INPUT 1 -s 192.168.222.204
|
|
...
|
|
|
|
++++++++++++++++++
|
|
Expected Behavior
|
|
++++++++++++++++++
|
|
The stadby controller(controller-1) becomes active
|
|
System host-list shows right states
|
|
controller-0 reboots if the BMC provisioned
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
HA_Cloud_Recovery_improvements_03
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
:Test ID: HA_Cloud_Recovery_improvements_03
|
|
:Test Title: test_split_brain-avd_aio_dx_direct_active_controller_lost
|
|
connection_to_standby_ip_table_drop_on_mgt_infra_and_oam
|
|
:Tags: P2,HA,Recovery improvement,regression
|
|
|
|
+++++++++++++++++++
|
|
Testcase Objective
|
|
+++++++++++++++++++
|
|
To verify split-brain scenario by triggering connection failure on MGT infra
|
|
and OAM on AIO-DX-Direct standby controller
|
|
|
|
++++++++++++++++++++
|
|
Test Pre-Conditions
|
|
++++++++++++++++++++
|
|
System should be a AIO-DX-Direct connected system
|
|
|
|
+++++++++++
|
|
Test Steps
|
|
+++++++++++
|
|
1. Provision BMC verify BMC provisioned.(if BMC not available there won't
|
|
be a reboot for loss of connection expected behavior at the time of
|
|
connection loss is different)
|
|
2. From standby controller to active controller to drop MGT infra and OAM.
|
|
Example as below.
|
|
code::
|
|
sudo iptables -I INPUT 1 -s 192.168.204.4 -j DROP && sudo iptables -I \
|
|
INPUT 1 -s 192.168.205.3 -j DROP && sudo iptables -I \
|
|
INPUT 1 -s 128.150.150.96 -j DROP
|
|
...
|
|
3. Verify loss of connectivity and alarm on active controller
|
|
|
|
++++++++++++++++++
|
|
Expected Behavior
|
|
++++++++++++++++++
|
|
Verify loss of connectivity and alarm on active controller
|
|
System host-list shows right states
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
HA_Cloud_Recovery_improvements_04
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
:Test ID: HA_Cloud_Recovery_improvements_04
|
|
:Test Title: test_split-brain-avd_active/standby_number_of_the_nodes_reachable
|
|
_changes_couple_of_times
|
|
:Tags: P2,HA,Recovery improvement,regression
|
|
|
|
++++++++++++++++++++
|
|
Testcase Objective:
|
|
++++++++++++++++++++
|
|
Purpose of this test is to verify Active standby controller selection criteria
|
|
on split brain scenario is based on healthier controller.This scenario will be
|
|
repeated after active standby selected and again connection failure on compute.
|
|
|
|
+++++++++++++++++++++
|
|
Test Pre-Conditions:
|
|
+++++++++++++++++++++
|
|
The system should have at least 3 or more computes with 2 controller.
|
|
|
|
+++++++++++
|
|
Test Steps
|
|
+++++++++++
|
|
|
|
1. From Active controller controller-0 block control and compute-0
|
|
communication (if management and infra provisioned both need to be blocked)
|
|
code::
|
|
sudo iptables -I INPUT 1 -s 192.168.223.57 -j DROP && sudo iptables\
|
|
-I INPUT 1 -s 192.168.222.156 -j DROP && sudo iptables -I INPUT 1 \
|
|
-s 192.168.222.4 -j DROP && sudo iptables -I INPUT 1 -s \
|
|
128.224.150.57 -j DROP
|
|
...
|
|
2. Verify connection failure alarm.
|
|
3. Verify swact
|
|
4. unblock compute-0 to controller-0 from controller-0 suing iptables command.
|
|
code::
|
|
sudo iptables -D INPUT -s 192.168.223.57 -j DROP && sudo iptables -D \
|
|
INPUT -s 192.168.222.156 -j DROP && sudo iptables -D INPUT -s \
|
|
192.168.222.4 -j DROP && sudo iptables -D INPUT -s 192.168.223.4 -j \
|
|
DROP
|
|
...
|
|
5. Repeat the above step current active controller block traffic on
|
|
controller-1 to compute-0
|
|
|
|
+++++++++++++++++++
|
|
Expected Behavior
|
|
+++++++++++++++++++
|
|
controller-1 becomes active
|
|
System host-list shows right states
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
HA_Cloud_Recovery_improvements_05
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
:Test ID: HA_Cloud_Recovery_improvements_05
|
|
:Test Title: test_MNFA_timeouts_2mins_1_hour
|
|
:Tags: P2,HA,Recovery improvement,regression
|
|
|
|
++++++++++++++++++++
|
|
Testcase Objective
|
|
++++++++++++++++++++
|
|
Purpose of this test is to validate the trigger of MNFA(Multi Node Failure
|
|
Avoidance) mode trigger on alarm based on different timeouts 2mins or 1 hour
|
|
|
|
+++++++++++++++++++++
|
|
Test Pre-Conditions
|
|
+++++++++++++++++++++
|
|
The system should have at least 3 or more computes with 2 controller.
|
|
|
|
+++++++++++
|
|
Test Steps
|
|
+++++++++++
|
|
1. From Active controller set mnfa_timeout (2mins or 1 hour ) on MNFA can
|
|
stay active before graceful recovery of affected hosts. Use below commands.
|
|
Eg:
|
|
code::
|
|
system service-parameter-list
|
|
system service-parameter-modify service=platform section=maintenance \
|
|
mnfa_timeout = 2 service
|
|
system service-parameter-apply platform
|
|
...
|
|
2. Apply the change and alarm 250.001 controller-0 Configuration is
|
|
out-of-date cleared using command
|
|
system service-parameter-apply platform
|
|
3. Trigger heart beat failure by powering off any nodes other than active
|
|
controller
|
|
4. Verify event-list --log to see below MNFA enter and exit. If the
|
|
mnfa_timeout is set to 120
|
|
seconds mnfa enter exit log time difference will be 120 seconds.
|
|
If is it set to 1 hour it will be 1hour. Below stings will be seen on alarm.
|
|
|
|
host=controller-1.event=mnfa_enter
|
|
host=controller-1.event=mnfa_exit
|
|
|
|
++++++++++++++++++
|
|
Expected Behavior
|
|
++++++++++++++++++
|
|
In the above test MNFA enter and exit would be triggered in event-list log
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
HA_Cloud_Recovery_improvements_06
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
:Test ID: HA_Cloud_Recovery_improvements_06
|
|
:Test Title: test_MNFA_timeouts_default
|
|
:Tags: P2,HA,Recovery improvement,regression
|
|
|
|
+++++++++++++++++++
|
|
Testcase Objective
|
|
+++++++++++++++++++
|
|
Purpose of this test is to validate the trigger of MNFA mode with the default
|
|
values.
|
|
|
|
++++++++++++++++++++
|
|
Test Pre-Conditions
|
|
++++++++++++++++++++
|
|
The system should have at least 3 or more computes with 2 controller.
|
|
|
|
+++++++++++
|
|
Test Steps
|
|
+++++++++++
|
|
|
|
1. From Active controller
|
|
Set mnfa_timeout (2mins or 1 hour ) on MNFA can stay active before graceful
|
|
recovery of affected hosts.
|
|
Eg:
|
|
To check current values for mnfa_timeout use system service-parameter-list
|
|
code::
|
|
system service-parameter-modify service=platform section=maintenance \
|
|
mnfa_timeout=<value>
|
|
system service-parameter-apply platform
|
|
2. Apply the change and alarm 250.001 controller-0 Configuration is
|
|
out-of-date cleared using command system service-parameter-apply platform
|
|
3. Trigger heart beat failure by powering off any nodes other than active
|
|
controller.
|
|
4. Verify system event-list --log to see below MNFA enter and exit.
|
|
5. Verify system hosts-list. It will show hosts as degraded when host is in
|
|
off-line during the MNFA enter and exit.
|
|
host=controller-1.event=mnfa_enter
|
|
host=controller-1.event=mnfa_exit
|
|
|
|
++++++++++++++++++
|
|
Expected Behavior
|
|
++++++++++++++++++
|
|
In the above test MNFA enter and exit would be triggered in event-list log
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
HA_Cloud_Recovery_improvements_07
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
:Test ID: HA_Cloud_Recovery_improvements_07
|
|
:Test Title: test_pull_management_and_OAM_cable_on_active_controller
|
|
:Tags: P2,HA,Recovery improvement,regression
|
|
|
|
++++++++++++++++++++
|
|
Testcase Objective:
|
|
++++++++++++++++++++
|
|
This test is to verify OAM & MGT cable pull alarm and swact
|
|
|
|
++++++++++++++++++++
|
|
Test Pre-Conditions:
|
|
++++++++++++++++++++
|
|
Any 2+2 system installed latest load.
|
|
|
|
+++++++++++
|
|
Test Steps
|
|
+++++++++++
|
|
|
|
1. Verify no alarms for fm alarm-list
|
|
2. Physically remove OAM and MGT cable on active controller(controller-0) cable
|
|
3. Verify alarm ID (400.005,200.005)
|
|
4. Verify standby controller(controller-0) was swacted sudo sm-dump
|
|
5. Verify system host-list on new active controller
|
|
all the hosts are available and standby controller off-line.
|
|
|
|
++++++++++++++++++
|
|
Expected Behavior
|
|
++++++++++++++++++
|
|
system swact with alarms for cable pull on OAM and MGT
|
|
|
|
:Test ID: HA_Cloud_Recovery_improvements_08
|
|
:Test Title: test_pull_management_cable_on_standby_controller
|
|
:Tags: P2,HA,Recovery improvement,regression
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
HA_Cloud_Recovery_improvements_08
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
++++++++++++++++++++
|
|
Testcase Objective:
|
|
++++++++++++++++++++
|
|
Pull management cable on standby and verify alarm.
|
|
|
|
++++++++++++++++++++
|
|
Test Pre-Conditions:
|
|
++++++++++++++++++++
|
|
Any 2+2 system installed latest load.
|
|
|
|
++++++++++++
|
|
Test Steps:
|
|
++++++++++++
|
|
|
|
1. Verify no alarms for fm alarm-list
|
|
2. Physically remove MGT cable on standby controller(controller-0) cable
|
|
3. Verify current alarm list fm alarm-list alarm id(400.005,200.005)
|
|
4. Verify no change in active controller and other hosts states standby
|
|
host will be off-line.
|
|
code ::
|
|
system host-list
|
|
...
|
|
|
|
++++++++++++++++++
|
|
Expected Behavior
|
|
++++++++++++++++++
|
|
Verify management failed alarm ID (400.005,200.005)
|
|
Verify hosts state system host-list
|
|
|
|
-----------
|
|
References:
|
|
-----------
|
|
https://wiki.openstack.org/wiki/StarlingX/Containers/Installationem
|